Improving Data Analysis using Vacuum Ultraviolet Automated Library Integrated Deconvolution on Gas Chromatography Vacuum Ultraviolet Spectroscopy Data

dc.contributor.advisorSolouki, Touradj
dc.contributor.authorWarar, Shubhneet
dc.contributor.departmentBiochemistry.en_US
dc.date.accessioned2021-05-18T13:01:10Z
dc.date.available2021-05-18T13:01:10Z
dc.date.copyright2021
dc.date.issued2021-05-18
dc.description.abstractGas chromatography (GC) coupled to vacuum ultraviolet (VUV) spectroscopy and mass spectrometry (MS) can provide confident chemical identities. Vacuum Ultraviolet Automated Library-Integrated Deconvolution (VALID), a custom-built software, is used to deconvolute congested GC-VUV data. This project assesses the performance of VALID and discusses methods to improve GC-VUV data analysis. Perfume and frankincense-based essential oil samples were injected into a home-built tandem GC/VUV-MS instrument and analyzed both manually and via VALID. VALID allowed for successful identification of GC-VUV retention-time convoluted analytes that could not be detected by manual analysis; analyte identifications were confirmed by GC retention index (RI) values. To address the limited dynamic range of the VUV spectrometer, GC-VUV data from samples at varying concentrations were obtained to acquire suitable VUV spectra that exhibited sufficient signal-to-noise levels with no signal saturation. More analytes were identified via the combination of manual VUV analysis, VALID, and GC RI analysis than using each of the three data analysis approaches alone. To address the limited size of the existing commercial VUV library, GC-MS library-searching was used to identify GC-VUV-convoluted compounds that were deconvoluted by VALID; these GC-MS identifications were used to label VALID-extracted VUV spectra for cost-effective and rapid expansion of the VUV libraries.en_US
dc.identifier.urihttps://hdl.handle.net/2104/11258
dc.language.isoen_USen_US
dc.rightsBaylor University projects are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission.en_US
dc.rights.accessrightsWorldwide access.en_US
dc.rights.accessrightsAccess changed 9/21/23.
dc.titleImproving Data Analysis using Vacuum Ultraviolet Automated Library Integrated Deconvolution on Gas Chromatography Vacuum Ultraviolet Spectroscopy Dataen_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Shubhneet_Warar_honorsthesis.pdf
Size:
2.28 MB
Format:
Adobe Portable Document Format
Description:
Thesis
No Thumbnail Available
Name:
ThesisCopyright&Availab.Form.pdf
Size:
1.2 MB
Format:
Adobe Portable Document Format
Description:
Permissions Form

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.87 KB
Format:
Item-specific license agreed upon to submission
Description: