The evaluation of a subsurface-flow constructed wetland for on-site wastewater treatment under the NSF/ANSI Standard 40 protocol design loading.
dc.contributor.advisor | Yelderman, Joe C. | |
dc.contributor.author | Davila, Pablo Arturo. | |
dc.contributor.department | Environmental Studies. | en |
dc.contributor.other | Baylor University. Dept. of Environmental Studies. | en |
dc.date.accessioned | 2007-02-21T23:07:33Z | |
dc.date.available | 2007-02-21T23:07:33Z | |
dc.date.copyright | 2006-12 | |
dc.date.issued | 2007-02-21T23:07:33Z | |
dc.description | Includes bibliographical references (p. 76-77). | en |
dc.description.abstract | A subsurface-flow constructed wetland was studied using the National Sanitation Foundation/ American National Standards Institute Standard 40 protocol for Class I on-site wastewater treatment systems at the Baylor Wastewater Research Program (BWRP) site within the Waco Metropolitan Area Regional Sewerage System (WMARSS) treatment plant, Waco, Texas. Raw wastewater from the WMARSS plant was pumped into a two-chambered 1,500 gallon septic tank and flowed by gravity into the 375 ft3 treatment wetland. Both septic tank and wetland effluent samples were analyzed for carbonaceous 5-day biochemical oxygen demand, total suspended solids, and nutrients. In addition, pH values were collected, as well as rainfall and temperature data. The study produced a TSS wetland effluent average of 11 mg/l (96 percent reduction) and CBOD wetland effluent average of 40 mg/l (84 percent reduction). Total nitrogen wetland effluent averaged 30 mg/l (19 percent reduction) and total phosphorus wetland effluent averaged 4.0 mg/l (31 percent reduction). | en |
dc.description.degree | M.S. | en |
dc.description.statementofresponsibility | by Pablo Arturo Davila. | en |
dc.format.extent | xii, 77 p. : ill. | en |
dc.format.extent | 404480 bytes | |
dc.format.extent | 110592 bytes | |
dc.format.extent | 14848 bytes | |
dc.format.extent | 27136 bytes | |
dc.format.extent | 26112 bytes | |
dc.format.extent | 538389 bytes | |
dc.format.extent | 2140060 bytes | |
dc.format.mimetype | application/vnd.ms-excel | |
dc.format.mimetype | application/vnd.ms-excel | |
dc.format.mimetype | application/vnd.ms-excel | |
dc.format.mimetype | application/vnd.ms-excel | |
dc.format.mimetype | application/vnd.ms-excel | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | application/pdf | |
dc.identifier.uri | http://hdl.handle.net/2104/4957 | |
dc.language.iso | en_US | en |
dc.rights | Baylor University theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact librarywebmaster@baylor.edu for inquiries about permission. | en |
dc.rights.accessrights | Worldwide access | en |
dc.subject | Constructed wetlands --- Waco (Tex.) -- Case studies. | en |
dc.subject | Sewage -- Purification -- Biological treatment --- Waco (Tex.) -- Case studies. | en |
dc.title | The evaluation of a subsurface-flow constructed wetland for on-site wastewater treatment under the NSF/ANSI Standard 40 protocol design loading. | en |
dc.type | Thesis | en |
Files
Original bundle
1 - 5 of 7
Loading...
- Name:
- pablo_davila_masters.pdf
- Size:
- 2.04 MB
- Format:
- Adobe Portable Document Format
- Description:
- Thesis
No Thumbnail Available
- Name:
- pablo_davila_permissions.pdf
- Size:
- 525.77 KB
- Format:
- Adobe Portable Document Format
- Description:
- Permissions Form
No Thumbnail Available
- Name:
- pablo_davila_appendix_H_i.xls
- Size:
- 25.5 KB
- Format:
- Microsoft Excel
- Description:
- Appendix H. TSS and CBOD data- Aqua Tech Laboratories
No Thumbnail Available
- Name:
- pablo_davila_appendix_H_ii.xls
- Size:
- 26.5 KB
- Format:
- Microsoft Excel
- Description:
- Appendix H. TSS and BOD data- City of Waco Utilities Services- Waco Regional Water Quality Laboratory
No Thumbnail Available
- Name:
- pablo_davila_appendix_H_iii.xls
- Size:
- 14.5 KB
- Format:
- Microsoft Excel
- Description:
- Appendix H. Nutrient data- Baylor University, Center for Reservoir and Aquatic Systems Research (CRASR)- Water Quality Database
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.96 KB
- Format:
- Item-specific license agreed upon to submission
- Description: