The evaluation of a subsurface-flow constructed wetland for on-site wastewater treatment under the NSF/ANSI Standard 40 protocol design loading.

dc.contributor.advisorYelderman, Joe C.
dc.contributor.authorDavila, Pablo Arturo.
dc.contributor.departmentEnvironmental Studies.en
dc.contributor.otherBaylor University. Dept. of Environmental Studies.en
dc.date.accessioned2007-02-21T23:07:33Z
dc.date.available2007-02-21T23:07:33Z
dc.date.copyright2006-12
dc.date.issued2007-02-21T23:07:33Z
dc.descriptionIncludes bibliographical references (p. 76-77).en
dc.description.abstractA subsurface-flow constructed wetland was studied using the National Sanitation Foundation/ American National Standards Institute Standard 40 protocol for Class I on-site wastewater treatment systems at the Baylor Wastewater Research Program (BWRP) site within the Waco Metropolitan Area Regional Sewerage System (WMARSS) treatment plant, Waco, Texas. Raw wastewater from the WMARSS plant was pumped into a two-chambered 1,500 gallon septic tank and flowed by gravity into the 375 ft3 treatment wetland. Both septic tank and wetland effluent samples were analyzed for carbonaceous 5-day biochemical oxygen demand, total suspended solids, and nutrients. In addition, pH values were collected, as well as rainfall and temperature data. The study produced a TSS wetland effluent average of 11 mg/l (96 percent reduction) and CBOD wetland effluent average of 40 mg/l (84 percent reduction). Total nitrogen wetland effluent averaged 30 mg/l (19 percent reduction) and total phosphorus wetland effluent averaged 4.0 mg/l (31 percent reduction).en
dc.description.degreeM.S.en
dc.description.statementofresponsibilityby Pablo Arturo Davila.en
dc.format.extentxii, 77 p. : ill.en
dc.format.extent404480 bytes
dc.format.extent110592 bytes
dc.format.extent14848 bytes
dc.format.extent27136 bytes
dc.format.extent26112 bytes
dc.format.extent538389 bytes
dc.format.extent2140060 bytes
dc.format.mimetypeapplication/vnd.ms-excel
dc.format.mimetypeapplication/vnd.ms-excel
dc.format.mimetypeapplication/vnd.ms-excel
dc.format.mimetypeapplication/vnd.ms-excel
dc.format.mimetypeapplication/vnd.ms-excel
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.identifier.urihttp://hdl.handle.net/2104/4957
dc.language.isoen_USen
dc.rightsBaylor University theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact librarywebmaster@baylor.edu for inquiries about permission.en
dc.rights.accessrightsWorldwide accessen
dc.subjectConstructed wetlands --- Waco (Tex.) -- Case studies.en
dc.subjectSewage -- Purification -- Biological treatment --- Waco (Tex.) -- Case studies.en
dc.titleThe evaluation of a subsurface-flow constructed wetland for on-site wastewater treatment under the NSF/ANSI Standard 40 protocol design loading.en
dc.typeThesisen

Files

Original bundle

Now showing 1 - 5 of 7
Loading...
Thumbnail Image
Name:
pablo_davila_masters.pdf
Size:
2.04 MB
Format:
Adobe Portable Document Format
Description:
Thesis
No Thumbnail Available
Name:
pablo_davila_permissions.pdf
Size:
525.77 KB
Format:
Adobe Portable Document Format
Description:
Permissions Form
No Thumbnail Available
Name:
pablo_davila_appendix_H_i.xls
Size:
25.5 KB
Format:
Microsoft Excel
Description:
Appendix H. TSS and CBOD data- Aqua Tech Laboratories
No Thumbnail Available
Name:
pablo_davila_appendix_H_ii.xls
Size:
26.5 KB
Format:
Microsoft Excel
Description:
Appendix H. TSS and BOD data- City of Waco Utilities Services- Waco Regional Water Quality Laboratory
No Thumbnail Available
Name:
pablo_davila_appendix_H_iii.xls
Size:
14.5 KB
Format:
Microsoft Excel
Description:
Appendix H. Nutrient data- Baylor University, Center for Reservoir and Aquatic Systems Research (CRASR)- Water Quality Database

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.96 KB
Format:
Item-specific license agreed upon to submission
Description: